Fresh air, properly moving

HRV & ERV Ventilation Service

A ventilation-system review focused on filters, core condition, fans, drainage, controls and accessible airflow paths for heat- or energy-recovery ventilators.

Maintenance or active fault

Know which problem the appointment needs to solve.

Routine service addresses filters, the recovery core, drainage, hoods and available fan operation. Failed controls, motors, dampers or a full airflow-balancing requirement are separate diagnostic or commissioning scopes.

01

Indoor air feels stale or window condensation has increased

02

The unit is noisy, will not enter boost mode or appears unresponsive

03

Water, frost or a drainage concern appears around the unit

04

Filters, core or exterior hoods are visibly restricted

Service vs. repair

The visit starts with the actual intent.

Routine service addresses filters, the recovery core, drainage, hoods and available fan operation. Failed controls, motors, dampers or a full airflow-balancing requirement are separate diagnostic or commissioning scopes.

Repair vs. replacement

Make the larger decision with evidence.

A replacement decision should consider cabinet and core condition, motor and control availability, duct configuration, required airflow and whether the existing installation can be corrected without replacing the unit.

See what's included

A clear service scope before the visit.

The booked appointment covers the confirmed service scope. If diagnosis reveals a separate repair or part, the customer should receive an explanation and price before authorizing additional work.

01

Ventilation-unit operating review

02

Filter and recovery-core condition review

03

Accessible cleaning and drainage review

04

15-point HRV/ERV framework

05

Clear findings and next-step explanation

Equipment-specific · not generic

The hrv / erv 15-point framework.

Each point explains what is reviewed and why it matters. Accessibility, equipment design, operating conditions and manufacturer requirements determine the exact steps completed.

  1. 01Service

    Equipment identification

    Confirm HRV or ERV type, controls, connected spaces and reported concern.

  2. 02Performance

    Wall control and modes

    Review normal, boost and available seasonal control response.

  3. 03Cleaning

    Supply and exhaust filters

    Inspect and clean or identify replacement needs for accessible filters.

  4. 04Cleaning

    Recovery core

    Inspect and service the core according to its type and available manufacturer guidance.

  5. 05Condition

    Core seals and cabinet

    Review accessible seals, latches and cabinet condition.

  6. 06Cleaning

    Condensate pan

    Inspect and clean accessible condensate collection areas on applicable equipment.

  7. 07Condition

    Drain and trap

    Review accessible drain routing, trap condition and evidence of blockage or leakage.

  8. 08Condition

    Exterior hoods

    Inspect accessible intake and exhaust hoods for obvious obstruction or damage.

  9. 09Condition

    Duct connections

    Review visible connections, insulation and signs of leakage or condensation.

  10. 10Performance

    Supply fan

    Observe fan operation, sound and available speed response.

  11. 11Performance

    Exhaust fan

    Observe fan operation, sound and available speed response.

  12. 12Condition

    Dampers

    Review accessible damper movement and condition where equipped.

  13. 13Performance

    Airflow indications

    Check available airflow at grilles or test ports; full balancing is a separate measured scope unless included.

  14. 14Safety

    Electrical components

    Inspect accessible power, wiring and controls for visible concerns.

  15. 15Service

    Final operation and report

    Reassemble, confirm operation and explain cleaning, observations and any balancing recommendation.

This framework communicates B.C HVAC's intended service structure. The assigned qualified professional confirms the safe, applicable and accessible work for the specific installation. It is not a substitute for the equipment manufacturer's service instructions.

A visible next step

How diagnosis becomes an informed decision.

The booked scope, any repair and any replacement estimate remain distinct so the customer can see what is being authorized.

  1. 01

    Describe comfort and moisture

    Share condensation, odour, noise, control and seasonal operating concerns.

  2. 02

    Review both air paths

    Supply, exhaust, filters, core, drainage, hoods and available control response are considered together.

  3. 03

    Separate service from balancing

    Routine cleaning, component repair and measured ventilation balancing are defined as separate scopes when appropriate.

Before you book

Questions customers ask.

Plain answers about price, scope, safety and what happens if the service identifies a repair.

Is full airflow balancing included?

Not automatically. A routine service can identify airflow concerns, while full system balancing requires dedicated measurements and should be confirmed as a separate scope if needed.

Can every recovery core be washed?

No. Core-care instructions vary, particularly between HRV and ERV media. Service should follow the equipment manufacturer's guidance.

Why is the condensate drain important?

Applicable HRVs can produce condensate. A restricted drain can lead to leakage, icing or poor operation.